Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Anal Chim Acta ; 1265: 341326, 2023 Jul 18.
Article in English | MEDLINE | ID: covidwho-2311677

ABSTRACT

Herein, we have proposed a straightforward and label-free electrochemical immunosensing strategy supported on a glassy carbon electrode (GCE) modified with a biocompatible and conducting biopolymer functionalized molybdenum disulfide-reduced graphene oxide (CS-MoS2/rGO) nanohybrid to investigate the SARS-CoV-2 virus. CS-MoS2/rGO nanohybrid-based immunosensor employs recombinant SARS-CoV-2 Spike RBD protein (rSP) that specifically identifies antibodies against the SARS-CoV-2 virus via differential pulse voltammetry (DPV). The antigen-antibody interaction diminishes the current responses of the immunosensor. The obtained results indicate that the fabricated immunosensor is extraordinarily capable of highly sensitive and specific detection of the corresponding SARS-CoV-2 antibodies with a LOD of 2.38 zg mL-1 in phosphate buffer saline (PBS) samples over a broad linear range between 10 zg mL-1-100 ng mL-1. In addition, the proposed immunosensor can detect attomolar concentrations in spiked human serum samples. The performance of this immunosensor is assessed using actual serum samples from COVID-19-infected patients. The proposed immunosensor can accurately and substantially differentiate between (+) positive and (-) negative samples. As a result, the nanohybrid can provide insight into the conception of Point-of-Care Testing (POCT) platforms for cutting-edge infectious disease diagnostic methods.


Subject(s)
Biosensing Techniques , COVID-19 , Graphite , Metal Nanoparticles , Humans , Molybdenum , Biosensing Techniques/methods , COVID-19/diagnosis , Immunoassay/methods , SARS-CoV-2 , Electrochemical Techniques/methods
2.
Bioeng Transl Med ; 8(3): e10481, 2023 May.
Article in English | MEDLINE | ID: covidwho-2310294

ABSTRACT

Microbial pathogens have threatened the world due to their pathogenicity and ability to spread in communities. The conventional laboratory-based diagnostics of microbes such as bacteria and viruses need bulky expensive experimental instruments and skilled personnel which limits their usage in resource-limited settings. The biosensors-based point-of-care (POC) diagnostics have shown huge potential to detect microbial pathogens in a faster, cost-effective, and user-friendly manner. The use of various transducers such as electrochemical and optical along with microfluidic integrated biosensors further enhances the sensitivity and selectivity of detection. Additionally, microfluidic-based biosensors offer the advantages of multiplexed detection of analyte and the ability to deal with nanoliters volume of fluid in an integrated portable platform. In the present review, we discussed the design and fabrication of POCT devices for the detection of microbial pathogens which include bacteria, viruses, fungi, and parasites. The electrochemical techniques and current advances in this field in terms of integrated electrochemical platforms that include mainly microfluidic- based approaches and smartphone and Internet-of-things (IoT) and Internet-of-Medical-Things (IoMT) integrated systems have been highlighted. Further, the availability of commercial biosensors for the detection of microbial pathogens will be briefed. In the end, the challenges while fabrication of POC biosensors and expected future advances in the field of biosensing have been discussed. The integrated biosensor-based platforms with the IoT/IoMT usually collect the data to track the community spread of infectious diseases which would be beneficial in terms of better preparedness for current and futuristic pandemics and is expected to prevent social and economic losses.

3.
J Mater Chem B ; 10(41): 8478-8489, 2022 10 26.
Article in English | MEDLINE | ID: covidwho-2050572

ABSTRACT

The outbreak of the highly contagious disease COVID-19, which is triggered by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), demands a rapid, low-cost, and highly sensitive immunosensor that can detect and identify the virus efficiently. Here, an electrochemical immunosensor based on a nanocomposite consisting of molybdenum disulfide nanosheets decorated with polydopamine (MoS2-PDA) is developed for highly sensitive detection of SARS-CoV-2 nucleocapsid protein (N protein). The MoS2-PDA nanocomposite possesses various hydroxyl and amine groups that have excellent chemistry with crosslinkers and act as adhesive agents to bind with the working electrode surface. Furthermore, the optical, functional, structural, vibrational, and morphological properties of the MoS2-PDA nanocomposite are studied using various characterization techniques such as UV-vis, FTIR, and Raman spectroscopies, XRD, and TEM. The electrochemical immunosensor is fabricated by functionalizing the MoS2-PDA nanocomposite with anti-SARS-CoV-2 nucleocapsid IgG antibody (Ab) and has a very high sensitivity against the N protein with a linear range between 10 ag mL-1 and 100 ng mL-1. The electrochemical immunosensor exhibits a lowest limit of detection (LOD) of 2.80 ag mL-1 and a limit of quantification (LOQ) of 8.48 ag mL-1via electrochemical impedance spectroscopy (EIS). Furthermore, the electrochemical immunosensor is successfully employed to detect the N protein in nasopharyngeal swab specimens and displays good consistency with the conventional RT-PCR test results. The results show that the MoS2-PDA nanocomposite-based electrochemical platform can serve as a highly sensitive and selective detector of N protein and will pave the way for the development of a point-of-care (POC) electrochemical immunosensor for rapid detection of other infectious viruses.


Subject(s)
Biosensing Techniques , COVID-19 , Humans , Molybdenum/chemistry , Biosensing Techniques/methods , Electrochemical Techniques/methods , Immunoassay , SARS-CoV-2 , COVID-19/diagnosis , Immunoglobulin G , Amines
4.
Computational Approaches for Novel Therapeutic and Diagnostic Designing to Mitigate SARS-CoV-2 Infection ; : 147-169, 2022.
Article in English | EuropePMC | ID: covidwho-1958359

ABSTRACT

Given the global Coronavirus disease-2019 (COVID-19) pandemic, the transmission, and mortality rate increased drastically and affected the healthcare, financial sectors, and livelihood of the common man. The use of conventional diagnostic tools like reverse transcription-polymerase chain reaction enabled to screen and detecting the spread at a normal pace that had few limitations embedded into their operation, such as complex operation, slow response time, inaccurate results, single laboratory-based operation, and limited sample processing capacity. Consequently, the biosensors have merits that helped in point of care testing, rapid response, simple operation, and multiplex detection among others. Moreover, other advancements in diagnostic tools provided the ability of multiplexing and multioperation attributes for the detection of severe acute respiratory syndrome-Coronavirus-2 that enabled the high-throughput diagnosis of the viral infection in real samples with faster and accurate results. Further, modifications in their methodology, design and detection strategy facilitated their high-throughput property to help in the effective management of the COVID-19 pandemic.

5.
ACS Appl Bio Mater ; 5(5): 2421-2430, 2022 05 16.
Article in English | MEDLINE | ID: covidwho-1829968

ABSTRACT

In this work, we report a facile synthesis of graphene oxide-gold (GO-Au) nanocomposites by electrodeposition. The fabricated electrochemical immunosensors are utilized for the dual detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigen and SARS-CoV-2 antibody. The GO-Au nanocomposites has been characterized by UV-vis spectroscopy, X-ray diffraction (XRD), transmission electron microscopy (TEM), cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS) for its biosensing properties. The linear detection range of the SARS-CoV-2 antigen immunosensor is 10.0 ag mL-1 to 50.0 ng mL-1, whereas that for the antibody immunosensor ranges from 1.0 fg mL-1 to 1.0 ng mL-1. The calculated limit of detection (LOD) of the SARS-CoV-2 antigen immunosensor is 3.99 ag mL-1, and that for SARS-CoV-2 antibody immunosensor is 1.0 fg mL-1 with high sensitivity. The validation of the immunosensor has also been carried out on patient serum and patient swab samples from COVID-19 patients. The results suggest successful utilization of the immunosensors with a very low detection limit enabling its use in clinical samples. Further work is needed for the standardization of the results and translation in screen-printed electrodes for use in portable commercial applications.


Subject(s)
Biosensing Techniques , COVID-19 , Metal Nanoparticles , Nanocomposites , Antibodies , Biosensing Techniques/methods , COVID-19/diagnosis , Gold/chemistry , Graphite , Humans , Immunoassay/methods , Metal Nanoparticles/chemistry , Nanocomposites/chemistry , SARS-CoV-2
6.
Mater Lett ; 305: 130824, 2021 Dec 15.
Article in English | MEDLINE | ID: covidwho-1401698

ABSTRACT

Unique characteristics like large surface area, excellent conductivity, functionality, ease of fabrication, etc., of graphene and its derivatives, have been extensively studied as potential candidates in healthcare applications. They have been utilized as a potential nanomaterial in biosensor fabrication for commercialized point-of-care (POC) devices. This review concisely provided innovative graphene and its derivative-based-IoT (Internet-of-Things) integrated electrochemical biosensor for accurate and advanced high-throughput testing of SARS-CoV-2 in POC setting.

7.
J Mater Chem B ; 9(23): 4620-4642, 2021 06 16.
Article in English | MEDLINE | ID: covidwho-1240778

ABSTRACT

Despite significant accomplishments in developing efficient rapid sensing systems and nano-therapeutics of higher efficacy, the recent coronavirus disease (COVID-19) pandemic is not under control successfully because the severe acute respiratory syndrome virus (SARS-CoV-2, original and mutated) transmits easily from human to -human and causes life-threatening respiratory disorders. Thus, it has become crucial to avoid this transmission through precautions and keep premises hygienic using high-performance anti-viral nanomaterials to trap and eradicate SARS-CoV-2. Such an antiviral nano-system has successfully demonstrated useful significant contribution in COVID-19 pandemic/endemic management effectively. However, their projection with potential sustainable prospects still requires considerable attention and efforts. With this aim, the presented review highlights various severe life-threatening viral infections and the role of multi-functional anti-viral nanostructures with manipulative properties investigated as an efficient precative shielding agent against viral infection progression. The salient features of such various nanostructures, antiviral mechanisms, and high impact multi-dimensional roles are systematically discussed in this review. Additionally, the challenges associated with the projection of alternative approaches also support the demand and significance of this selected scientific topic. The outcomes of this review will certainly be useful to motivate scholars of various expertise who are planning future research in the field of investigating sustainable and affordable high-performance nano-systems of desired antiviral performance to manage not only COVID-19 infection but other targeted viral infections as well.


Subject(s)
Antiviral Agents/pharmacology , COVID-19/prevention & control , Coated Materials, Biocompatible/chemistry , Models, Biological , Nanostructures/chemistry , Antiviral Agents/chemistry , COVID-19/epidemiology , COVID-19/virology , Coated Materials, Biocompatible/pharmacology , Humans , Nanostructures/therapeutic use , SARS-CoV-2/isolation & purification
8.
Int Rev Immunol ; 40(1-2): 126-142, 2021.
Article in English | MEDLINE | ID: covidwho-1236151

ABSTRACT

Coronavirus disease (COVID-19) is an emerging and highly infectious disease making global public health concern and socio-economic burden. It is caused due to Severe Acute Respiratory Syndrome Coronavirus (SARS-CoV-2). It has the tendency to spread rapidly through person-to-person. Currently, several molecular diagnostic platforms such as PCR, qRT-PCR, reverse transcription loop-mediated isothermal amplification (RT-LAMP), CRISPR are utilized for the diagnosis of SARS-CoV-2. These conventional techniques are costly, time consuming and require sophisticated instrumentation facility with well trained personnel for testing. Hence, it is tough to provide testing en-masse to the people in developing countries. On the other hand, several serological biosensors such as lateral flow immunosensor, optical, electrochemical, microfluidics integrated electrochemical/fluorescence is currently utilized for the diagnosis of SARS-CoV-2. In current pandemic situation, there is an urgent need of rapid and efficient diagnosis on mass scale of SARS-CoV-2 for early stage detection. Early monitoring of viral infections can help to control and prevent the spreading of infections in large chunk of population. In this review, the SARS-CoV-2 and their biomarkers in biological samples, collection of samples and recently reported potential electrochemical immunosensors for the rapid diagnosis of SARS-CoV-2 are discussed.


Subject(s)
Biosensing Techniques/methods , COVID-19 Serological Testing/methods , COVID-19/diagnosis , Electrochemical Techniques/methods , SARS-CoV-2/immunology , COVID-19 Nucleic Acid Testing/methods , Humans , Immunoassay/methods , Molecular Diagnostic Techniques/methods , Point-of-Care Systems , SARS-CoV-2/genetics
9.
ACS Appl Bio Mater ; 4(4): 2974-2995, 2021 04 19.
Article in English | MEDLINE | ID: covidwho-1157888

ABSTRACT

The current scenario, an ongoing pandemic of COVID-19, places a dreadful burden on the healthcare system worldwide. Subsequently, there is a need for a rapid, user-friendly, and inexpensive on-site monitoring system for diagnosis. The early and rapid diagnosis of SARS-CoV-2 plays an important role in combating the outbreak. Although conventional methods such as PCR, RT-PCR, and ELISA, etc., offer a gold-standard solution to manage the pandemic, they cannot be implemented as a point-of-care (POC) testing arrangement. Moreover, surface-enhanced Raman spectroscopy (SERS) having a high enhancement factor provides quantitative results with high specificity, sensitivity, and multiplex detection ability but lacks in POC setup. In contrast, POC devices such as lateral flow immunoassay (LFIA) offer rapid, simple-to-use, cost-effective, reliable platform. However, LFIA has limitations in quantitative and sensitive analyses of SARS-CoV-2 detection. To resolve these concerns, herein we discuss a unique modality that is an integration of SERS with LFIA for quantitative analyses of SARS-CoV-2. The miniaturization ability of SERS-based devices makes them promising in biosensor application and has the potential to make a better alternative of conventional diagnostic methods. This review also demonstrates the commercially available and FDA/ICMR approved LFIA kits for on-site diagnosis of SARS-CoV-2.


Subject(s)
COVID-19/diagnosis , Immunoassay/methods , Point-of-Care Systems , Spectrum Analysis, Raman , Viral Proteins/immunology , Antibodies, Immobilized/chemistry , Antibodies, Immobilized/immunology , Antibodies, Viral/blood , Antibodies, Viral/immunology , Biomarkers/blood , Biomarkers/metabolism , COVID-19/virology , Humans , SARS-CoV-2/isolation & purification , SARS-CoV-2/metabolism , Viral Proteins/metabolism
10.
ACS Appl Bio Mater ; 3(11): 7326-7343, 2020 11 16.
Article in English | MEDLINE | ID: covidwho-872634

ABSTRACT

Efficient and rapid detection of viruses plays an extremely important role in disease prevention, diagnosis, and environmental monitoring. Early screening of viral infection among the population has the potential to combat the spread of infection. However, the traditional methods of virus detection being used currently, such as plate culturing and quantitative RT-PCR, give promising results, but they are time-consuming and require expert analysis and costly equipment and reagents; therefore, they are not affordable by people in low socio-economic groups in developing countries. Further, mass or bulk testing chosen by many governments to tackle the pandemic situation has led to severe shortages of testing kits and reagents and hence are affecting the demand and supply chain drastically. We tried to include all the reported current scenario-based biosensors such as electrochemical, optical, and microfluidics, which have the potential to replace mainstream diagnostic methods and therefore could pave the way to combat COVID-19. Apart from this, we have also provided information on commercially available biosensors for detection of SARS-CoV-2 along with the challenges in development of better diagnostic approaches. It is therefore expected that the content of this review will help researchers to design and develop more sensitive advanced commercial biosensor devices for early diagnosis of viral infection, which can open up avenues for better and more specific therapeutic outcomes.


Subject(s)
COVID-19/diagnosis , Pandemics , Point-of-Care Systems , Biosensing Techniques , COVID-19/epidemiology , COVID-19/virology , Humans , SARS-CoV-2/isolation & purification